![]() The speed of response is reduced for long runs.They should be kept as short as possible.Care should be taken to ensure that the tubing/piping does not rest on or against any abrasive surface. Where redundant instrument sensing lines penetrate a wall or floor the required separation (Minimum 450 mm) should be maintained.Routing of instrument sensing lines should ensure that the lines are not subjected to vibrations, abnormal heat or stress.Instrument sensing lines should be run along the walls, columns or ceilings wherever practicable, avoiding open or exposed area to decrease the likelihood of persons supporting themselves on the lines or of damage to the sensing lines by pipe whip, jet forces or falling objects. ![]() As an alternate a suitable steel or concrete barrier can be used.